Diaphragm pumps FM917 and FM1101
Fürgut miniature diaphragm pumps for 6, 12 and 24 V
Diaphragm pumps also convey humid gases and liquids and are suitable for aggressive media. Fürgut builds them with Ryton or PA housings and precise DC motors.
The FM917 and FM1101 are each available for 6, 12 and 24 V.
Flow rate
up to 1.79 l/min
Vacuum
up to 340 mbar
Pressure
up to 555 mbar
Voltage
6, 12 and 24 V
Why a diaphragm pump?
The diaphragm completely separates the medium from the drive. This makes the pump insensitive to moisture and suitable for liquids and aggressive gases.
- For humid gases and liquids
- Well suited to aggressive media
- Low current consumption
- Long service life at reduced voltage
- Housing made of Ryton or PA
Typical applications
Analysers
Conveying gas and liquid samples.
Medical technology
Small, quiet pumps for devices.
Dosing
Conveying small quantities of liquid.
Environmental measurement
Humid samples without condensate problems.
Technical data
Types: FM917 F6V, FM917 F12V, FM917 F24V, FM1101 F6V, FM1101 F12V, FM1101 F24V. Each pump is specified at several operating voltages: at rated voltage and at reduced voltage. The current applies at minimum and maximum load in each case.
FM917
| Type | Item no. | Diaphragm | Weight | Rated current | Operating voltage | Flow rate | Vacuum operation | Pressure operation | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [g] | [mA] | [V] | [l/min] | Current min. [mA] | Current max. [mA] | [mbar] | [dB(A)] | Current min. [mA] | Current max. [mA] | [mbar] | [dB(A)] | |||
| FM917 F6V= | 0917060 | Silicone | 29 | 370 | 6 | 0,84 | 45 | 48 | 220 | – | 45 | 60 | 200 | – |
| 4,5 | 0,85 | 44 | 49 | 240 | – | 40 | 50 | 220 | – | |||||
| 3 | 0,32 | 36 | 42 | 260 | – | 32 | 50 | 240 | – | |||||
| 2 | 0,32 | 23 | 43 | 260 | – | 23 | 47 | 240 | – | |||||
| 1,5 | 0,57 | 20 | 50 | 270 | – | 19 | 50 | 400 | – | |||||
| FM917 F12V= | 0917012 | Silicone | 29 | 320 | 9 | 0,93 | 35 | 38 | 190 | – | 31 | 38 | 160 | – |
| 6 | 0,53 | 33 | 34 | 210 | – | 25 | 39 | 230 | – | |||||
| 4,5 | 0,33 | 26 | 34 | 220 | – | 22 | 38 | 240 | – | |||||
| 3 | 0,32 | 21 | 36 | 230 | – | 17 | 40 | 250 | – | |||||
| FM917 F24V= | 0917024 | Silicone | 29 | 140 | 15 | 0,94 | 22 | 23 | 190 | – | 21 | 26 | 180 | – |
| 12 | 0,65 | 20 | 21 | 210 | – | 19 | 25 | 220 | – | |||||
| 9 | 0,37 | 17 | 20 | 220 | – | 17 | 25 | 220 | – | |||||
| 6 | 0,29 | 13 | 20 | 230 | – | 14 | 23 | 240 | – | |||||
| 4,5 | 0,37 | 11 | 20 | 230 | – | 13 | 23 | 240 | – | |||||
FM1101
| Type | Item no. | Diaphragm | Weight | Rated current | Operating voltage | Flow rate | Vacuum operation | Pressure operation | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [g] | [mA] | [V] | [l/min] | Current min. [mA] | Current max. [mA] | [mbar] | [dB(A)] | Current min. [mA] | Current max. [mA] | [mbar] | [dB(A)] | |||
| FM1101 F6V= | 0112101 | Silicone | 37 | 370 | 6,0 | 1,27 | 110 | 120 | 265 | 74 | 85 | 105 | 315 | 72 |
| 4,5 | 0,96 | 95 | 125 | 305 | 70 | 65 | 105 | 415 | 66 | |||||
| 3,0 | 0,65 | 60 | 105 | 300 | 55 | 60 | 110 | 325 | 54 | |||||
| 0112115 | EPDM | 37 | 370 | 6,0 | 1,56 | 105 | 135 | 260 | 72 | 100 | 125 | 335 | 76 | |
| 4,5 | 1,06 | 85 | 140 | 300 | 64 | 85 | 145 | 415 | 66 | |||||
| 3,0 | 0,60 | 70 | 130 | 300 | 62 | 70 | 140 | 210 | 60 | |||||
| 0112126 | Viton | 37 | 370 | 6,0 | 0,75 | 150 | 195 | 330 | 59 | 150 | 175 | 555 | 66 | |
| 4,5 | 0,53 | 125 | 190 | 295 | 54 | 140 | 195 | 485 | 60 | |||||
| 3,0 | 0,35 | 110 | 155 | 110 | 45 | 125 | 170 | 130 | 45 | |||||
| FM1101 F12V= | 0114001 | Silicone | 37 | 320 | 12,0 | 1,79 | 90 | 90 | 185 | 72 | 85 | 95 | 280 | 72 |
| 9,0 | 1,16 | 75 | 90 | 235 | 69 | 70 | 100 | 340 | 65 | |||||
| 6,0 | 0,75 | 60 | 90 | 195 | 64 | 60 | 100 | 250 | 57 | |||||
| 0114015 | EPDM | 37 | 320 | 12,0 | 1,78 | 70 | 75 | 250 | 75 | 70 | 80 | 310 | 78 | |
| 9,0 | 1,36 | 60 | 70 | 340 | 71 | 60 | 90 | 445 | 70 | |||||
| 6,0 | 0,75 | 50 | 70 | 320 | 66 | 50 | 90 | 370 | 65 | |||||
| 0114026 | Viton | 37 | 320 | 12,0 | 1,05 | 105 | 120 | 240 | 63 | 125 | 125 | 280 | 66 | |
| 9,0 | 0,75 | 95 | 120 | 195 | 62 | 115 | 115 | 210 | 62 | |||||
| 6,0 | 0,56 | 90 | 115 | 90 | 55 | 115 | 115 | 95 | 56 | |||||
| FM1101 F24V= | 0116001 | Silicone | 37 | 140 | 18,0 | 1,27 | 50 | 60 | 240 | 69 | 50 | 65 | 315 | 67 |
| 15,0 | 1,01 | 50 | 60 | 250 | 67 | 50 | 65 | 315 | 62 | |||||
| 12,0 | 0,75 | 45 | 55 | 230 | 59 | 45 | 60 | 260 | 58 | |||||
| 0116015 | EPDM | 37 | 140 | 18,0 | 1,42 | 45 | 55 | 310 | 71 | 45 | 50 | 400 | 77 | |
| 15,0 | 1,22 | 40 | 55 | 145 | 63 | 40 | 50 | 460 | 69 | |||||
| 12,0 | 0,80 | 35 | 55 | 170 | 58 | 35 | 60 | 450 | 60 | |||||
| 0116026 | Viton | 37 | 140 | 18,0 | 0,75 | 70 | 80 | 255 | 59 | 65 | 70 | 520 | 62 | |
| 15,0 | 0,55 | 60 | 75 | 290 | 53 | 60 | 70 | 500 | 59 | |||||
| 12,0 | 0,45 | 55 | 70 | 220 | 52 | 55 | 75 | 350 | 52 | |||||
Diaphragm pump for non-toxic and non-explosive gases / liquids
Illustrations/data/diagrams not binding
Dimensions
| Type | Length [mm] | Width [mm] | Height [mm] | Motor Ø [mm] | Connection nozzle [mm] | Connection spacing [mm] |
|---|---|---|---|---|---|---|
| FM917 | 37,7 | 17 | 25,3 | 16 | Ø 3,5 / Ø 2,95 | 7 |
| FM1101 | 42,2 | 22 | 36,5 | 16 | Ø 4 / Ø 3,4 | 9 |
Frequently asked questions
Which media can be conveyed?
The diaphragm pumps are designed for non-toxic and non-explosive gases and liquids. For other media, we will be glad to advise you.
Can I run the pump at a lower voltage?
Yes. The DC pumps can be operated at reduced voltage; flow rate and pressure then decrease and service life increases. The table shows the values for several voltages.
Are the pumps suitable for installation in devices?
Yes, that is what they are made for: small, light and with low current consumption, for example for analysers, medical and laboratory technology. For series production, we define the right version with you.
Where can I get pumps and spare parts?
From us. We supply Fürgut pumps individually and for series production, advise you on the selection and obtain replacements when a pump needs to be exchanged after many operating hours.
Downloads

Which pump suits your device?
Flow rate, pressure or vacuum, voltage and installation space determine the choice. We advise you and supply the right Fürgut pump, including for series production.