Side channel blower type TS
Two impellers, single-stage – up to 2,106 m³/h
In type TS, two impellers work side by side. They deliver in parallel and so almost double the flow rate, at the same pressure level as a single-stage blower.
This makes type TS the series for large air volumes: more than 2,100 m³/h with a single machine.
Flow rate
up to 2,106 m³/h
Pressure
up to 375 mbar
Vacuum
up to 300 mbar
Motor power
3 to 22 kW
Why type TS?
Where an application needs a lot of air at moderate pressure, one type TS often replaces two smaller blowers. This saves space, connections and maintenance work.
Sizes e07 to e12 belong to the EVO generation with the Smartwave™ impeller and run correspondingly more quietly.
- Oil-free: the air only comes into contact with the impeller, not with lubricants
- Direct drive: the impeller sits on the motor shaft, without belts or gearbox
- Non-contact and low-wear: apart from the bearings, there are no parts that wear
- Built for continuous operation: IE3 motors, IP55 protection, insulation class F
- Pressure or vacuum with the same machine
- Light, robust die-cast aluminium housing
Typical applications
Aeration of large tanks
Plenty of air for wastewater treatment plants and biological tanks with shallow water depth.
Pneumatic conveying
Large air volumes for conveying bulk materials over short to medium distances.
Drying
Wide drying and blow-off lines with several air knives.
Extraction
Central extraction systems with many suction points.
Technical data
| Model | Max. flow rate [m³/h] | Max. pressure [mbar] | Max. vacuum [mbar] | Motor [kW] |
|---|---|---|---|---|
| K05 TS | 408 | 250 | 225 | 3 – 4 |
| K05-66 TS | 334 | 235 | 210 | 4 |
| K06 TS | 562 | 300 | 250 | 4 – 7,5 |
| e07 TS | 830 | 325 | 225 | 5,5 – 11 |
| e08 TS | 1012 | 375 | 300 | 7,5 – 15 |
| e09 TS | 1326 | 375 | 300 | 11 – 18,5 |
| e10 TS | 1579 | 275 | 275 | 11 – 18,5 |
| e11 TS | 1856 | 275 | 300 | 15 – 22 |
| e12 TS | 2106 | 250 | 250 | 15 – 22 |
Values at 50 Hz according to the FPZ catalogue. The motor power depends on the operating point; at 60 Hz, flow rate and power are higher. We will be happy to size the right model for your operating point.
Frequently asked questions
What is the difference between type TS and type MS?
Type TS has two impellers delivering in parallel. At a similar pressure, it delivers considerably more air. If your application mainly needs more pressure, a two-stage blower (MD or TD) is the better choice.
Can the same blower generate pressure and vacuum?
Yes. A side channel blower blows on the pressure side and sucks on the suction side. Whether you use it as a blower or a vacuum generator depends only on which side you connect. The achievable values differ; see the table.
Do the values also apply at 60 Hz or with a frequency inverter?
The table shows the values at 50 Hz. At 60 Hz or with a frequency inverter, flow rate and power increase; this also allows the blower to be controlled precisely to demand. The 60 Hz values are in the catalogue.
Which accessories do I need?
At least an inlet filter and a pressure or vacuum relief valve that protects the blower against overload. Depending on the system, silencers, a check valve, a pressure gauge and an acoustic enclosure are added. Everything fits together and comes from a single source – us; see Accessories.
How much maintenance does a side channel blower need?
Very little. The impeller runs without contact, and there is neither oil nor belt. The main things to check are the inlet filter and, after many operating hours, the bearings. On request, we take care of maintenance and repair for you.
Downloads

Which blower suits your application?
Flow rate, pressure or vacuum, the conveyed medium and the operating times determine which series and size are right. We size the blower with you, supply the matching accessories and take care of installation and service.