Zum Inhalt springen

Rotary vane pumps DC03 to DC08

Fürgut DC../03., DC../04/20. and DC../08/20.

Fürgut’s smallest rotary vane pumps convey gases oil-free, with almost no pulsation and very low current consumption. They work as vacuum or pressure pumps.

The flow can be set linearly via the voltage; at reduced voltage they last particularly long.

Flow rate

up to 3 l/min

Vacuum

up to 280 mbar

Pressure

up to 305 mbar

Drive

Direct current

Why the DC03 to DC08?

A rotor with special carbon vanes turns in a stainless steel housing and conveys the gas evenly, without oil. The precision motor needs little power, making it ideal for battery-powered and portable devices.

  • Virtually pulsation-free delivery
  • Flow rate linearly adjustable via the voltage
  • Very low current consumption
  • Very long service life at reduced voltage
  • Oil-free, special carbon vanes

Typical applications

Gas analysis

Sampling for measuring instruments and gas warning systems.

Medical technology

Small pumps for patient-side devices.

Laboratory

Conveying and extracting gas in analysers.

Portable devices

Little power, little weight.

Technical data

Types: DC../03., DC../04/20., DC../08/20.. Each pump is specified at several operating voltages: at rated voltage and at reduced voltage. The current applies at minimum and maximum load in each case.

DC../03F

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[g][mA][V][l/min]Current min. [mA]Current max. [mA][mbar][dB(A)]Current min. [mA]Current max. [mA][mbar][dB(A)]
DC06/03F13235333706,00,92403501356024035012557
4,50,71802201055518022010054
3,00,511515045501151506550
DC12/03F153103332012,01,12053201805520031518559
9,00,81452401355414523514056
6,00,6951608546951608550
DC24/03F163003314024,00,91502151356415021514568
18,00,612017095611201758061
12,00,5901254557901256558
Rotary vane pumps DC03 to DC08: DC../03F

DC../04/20F

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[g][mA][V][l/min]Current min. [mA]Current max. [mA][mbar][dB(A)]Current min. [mA]Current max. [mA][mbar][dB(A)]
DC06/04/20F13300573706,01,61803001706118030517064
4,51,21252101106013022011057
3,00,9801356053801406051
DC09/04/20F14712573209,01,71652902156316529521561
7,51,51302401706313023016061
4,50,9651308056701257053
DC12/04/20F153175725012,01,61301901607213020518563
9,01,390145115649015012559
6,00,95590656155707054
DC24/04/20F163125714024,02,0951552806710017030565
18,01,670115205637012021060
12,01,1457512556508012055
Rotary vane pumps DC03 to DC08: DC../04/20F

DC../08/20F

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[g][mA][V][l/min]Current min. [mA]Current max. [mA][mbar][dB(A)]Current min. [mA]Current max. [mA][mbar][dB(A)]
DC06/08/20F13320603706,02,02003051206120031512058
4,51,613522580561352208056
3,01,1801304052801304551
DC09/08/20F14716603209,02,32153251755821532517563
7,52,01702651355617026513556
4,51,3901507051901507053
DC12/08/20F153206025012,02,51702601656717527015062
9,01,91151851056411519510557
6,01,4751156058751206054
DC24/08/20F163206014024,03,01101752057311017520571
18,02,580135145698012514066
12,01,950859062501206561
Rotary vane pumps DC03 to DC08: DC../08/20F

Rotary vane pump for non-toxic and non-explosive gases (DC../03F)
Rotary vane pump for non-toxic, non-flammable and non-explosive gases (DC../04/20F, DC../08/20F)
Illustrations/data/diagrams not binding

Dimensions

TypeLength [mm]Motor Ø [mm]Pump head [mm]Connection nozzle [mm]Connection spacing [mm]Electrical connection
DC../03F39,61616 × 20Ø 4 / Ø 3,48Leads 145 mm
DC../04/20F45,71620 × 20Ø 3,4 / Ø 2,214,8Leads 145 mm
DC../08/20F47,71620 × 20Ø 3,4 / Ø 2,214,8Leads 145 mm
Rotary vane pumps DC03 to DC08 – dimensions

Frequently asked questions

Which gases can be conveyed?

The pumps are designed for non-toxic, non-flammable and non-explosive gases. For other media, we will be glad to advise you on alternatives.

Can I run the pump at a lower voltage?

Yes. The DC pumps can be operated at reduced voltage; flow rate and pressure then decrease and service life increases. The table shows the values for several voltages.

How long does a miniature rotary vane pump last?

Depending on the load, the special carbon vanes reach up to 10,000 operating hours. At reduced voltage and low load they last particularly long.

Are the pumps suitable for installation in devices?

Yes, that is what they are made for: small, light and with low current consumption, for example for analysers, medical and laboratory technology. For series production, we define the right version with you.

Where can I get pumps and spare parts?

From us. We supply Fürgut pumps individually and for series production, advise you on the selection and obtain replacements when a pump needs to be exchanged after many operating hours.

Downloads

Which pump suits your device?

Flow rate, pressure or vacuum, voltage and installation space determine the choice. We advise you and supply the right Fürgut pump, including for series production.

Your quote in three steps

New system, spare parts or maintenance: tell us what you need. We will get back to you personally with a quote tailored to your application.

Your request
Topic

Your details

Your enquiry

Fields marked with * are required. We only use your details to process your enquiry; more in our privacy policy.