CompAir L160 to L250
Oil-lubricated screw compressors 160 to 250 kW – single-stage and two-stage FourCore
CompAir’s large screw compressors supply entire plants with compressed air. They deliver more air on a smaller footprint, run more quietly and feature a split radial fan and a new controller.
Alongside the proven single-stage series with over 1,000 installations worldwide, there are the two-stage FourCore models, which are up to 8% more efficient.
Motor power
160 to 250 kW
Pressure
5 to 13 bar
Design
single- and two-stage
Why the L160 to L250?
The FourCore GD10-DS compression stage works with four gears instead of three. This allows the speeds of both stages to be adjusted independently, and the compressor achieves the best efficiency at every pressure and speed.
The oil filter, check valves and thermostatic valves are integrated into the compression stage. Fewer connections and pipes mean fewer leaks and simpler maintenance.
- Two-stage FourCore models up to 8% more efficient
- One of the smallest footprints in its class
- Premium compression stage for high reliability
- Automatic motor lubrication
- Fixed or variable speed
- Delcos XL touchscreen controller with iConn
Product images




Technical data
L110FC – L290FC with fixed speed
| Compressor model | Operating pressure | Drive motor | Flow rate¹⁾ | Sound pressure level²⁾ | Weight | Dimensions L × W × H |
|---|---|---|---|---|---|---|
| [bar g] | [kW] | [m³/min] | [dB(A)] | [kg] | [mm] | |
| L110FC | 7,5 | 110 | 24,05 | 72 | 4483 | 2907 × 2071 × 2193 |
| 8,5 | 110 | 22,56 | 72 | 4483 | 2907 × 2071 × 2193 | |
| 10 | 110 | 21,21 | 72 | 4483 | 2907 × 2071 × 2193 | |
| L132FC | 7,5 | 132 | 28,79 | 73 | 4498 | 2907 × 2071 × 2193 |
| 8,5 | 132 | 25,27 | 73 | 4498 | 2907 × 2071 × 2193 | |
| 10 | 132 | 25,24 | 73 | 4498 | 2907 × 2071 × 2193 | |
| L160FC | 7,5 | 160 | 33,67 | 75 | 4542 | 2907 × 2071 × 2193 |
| 10 | 160 | 29,14 | 75 | 4542 | 2907 × 2071 × 2193 | |
| L200FC | 7,5 | 200 | 40,09 | 76 | 4765 | 2907 × 2071 × 2193 |
| 10 | 200 | 35,64 | 76 | 4765 | 2907 × 2071 × 2193 | |
| L250FC | 7,5 | 250 | 42,62 | 77 | 4975 | 2907 × 2071 × 2193 |
| 10 | 250 | 38,69 | 77 | 4675 | 2907 × 2071 × 2193 | |
| L290FC | 7,5 | 250 | 47,84 | 78 | 5000 | 2907 × 2071 × 2193 |
| 10 | 250 | 45,08 | 78 | 5000 | 2907 × 2071 × 2193 |
L110FC RS – L290FC RS with variable speed drive
| Compressor model | Operating pressure | Drive motor | Flow rate¹⁾ | Sound pressure level²⁾ at 70% load | Weight | Dimensions L × W × H |
|---|---|---|---|---|---|---|
| [bar g] | [kW] | [m³/min] | [dB(A)] | [kg] | [mm] | |
| L110FC RS | 6 – 10 | 110 | 9,16 – 24,69 | 72 | 4672 | 2907 × 2071 × 2193 |
| L132FC RS | 6 – 10 | 132 | 9,16 – 29,39 | 72 | 4736 | 2907 × 2071 × 2193 |
| L160FC RS | 5 – 10 | 160 | 9,61 – 32,07 | 74 | 4783 | 2907 × 2071 × 2193 |
| L200FC RS | 5 – 10 | 200 | 9,37 – 39,14 | 76 | 5083 | 2907 × 2071 × 2193 |
| L250FC RS | 5 – 10 | 250 | 9,37 – 42,97 | 77 | 5253 | 2907 × 2071 × 2193 |
| L290FC RS | 5 – 10 | 250 | 9,37 – 47,98 | 78 | 5268 | 2907 × 2071 × 2193 |
¹⁾ Data measured and stated in accordance with ISO 1217, Ed. 4, Annex C & Annex E, within the tolerances given below: inlet pressure 1 bar a, inlet temperature 20 °C, relative humidity 0% (dry).
²⁾ Free-field sound measurement in accordance with ISO 2151, tolerance ± 3 dB.
All models are also available as water-cooled versions. Please refer to the technical data sheet for the technical description.
L160 – L290 with fixed speed
| Compressor model | Operating pressure | Drive motor | Flow rate¹⁾ | Sound pressure level²⁾ | Weight | Dimensions L × W × H |
|---|---|---|---|---|---|---|
| [bar g] | [kW] | [m³/min] | [dB(A)] | [kg] | [mm] | |
| L160 | 7,5 | 160 | 32,04 | 76 | 4186 | 2949 × 2111 × 2193 |
| 10 | 160 | 28,20 | 76 | 4186 | 2949 × 2111 × 2193 | |
| 13 | 160 | 23,91 | 76 | 4186 | 2949 × 2111 × 2193 | |
| L200 | 7,5 | 200 | 39,23 | 77 | 4415 | 2949 × 2111 × 2193 |
| 10 | 200 | 34,85 | 77 | 4415 | 2949 × 2111 × 2193 | |
| 13 | 200 | 29,38 | 77 | 4415 | 2949 × 2111 × 2193 | |
| L250 | 7,5 | 250 | 42,03 | 78 | 4625 | 2949 × 2111 × 2193 |
| 10 | 250 | 37,01 | 78 | 4625 | 2949 × 2111 × 2193 | |
| 13 | 250 | 32,64 | 78 | 4625 | 2949 × 2111 × 2193 | |
| L290 | 7,5 | 250 | 47,10 | 79 | 4650 | 2949 × 2111 × 2193 |
| 10 | 250 | 41,53 | 79 | 4650 | 2949 × 2111 × 2193 | |
| 13 | 250 | 36,44 | 79 | 4650 | 2949 × 2111 × 2193 |
L160RS – L290RS with variable speed drive
| Compressor model | Operating pressure | Drive motor | Flow rate¹⁾ | Sound pressure level²⁾ at 70% load | Weight | Dimensions L × W × H |
|---|---|---|---|---|---|---|
| [bar g] | [kW] | [m³/min] | [dB(A)] | [kg] | [mm] | |
| L160RS | 5 – 13 | 160 | 6,54 – 32,33 | 75 | 4378 | 2949 × 2111 × 2193 |
| L200RS | 5 – 13 | 200 | 5,99 – 39,44 | 77 | 4573 | 2949 × 2111 × 2193 |
| L250RS | 5 – 13 | 250 | 5,83 – 42,80 | 78 | 4669 | 2949 × 2111 × 2193 |
| L290RS | 5 – 13 | 250 | 5,87 – 47,02 | 79 | 4684 | 2949 × 2111 × 2193 |
¹⁾ Data measured and stated in accordance with ISO 1217, Ed. 4, Annex C & Annex E, within the tolerances given below: inlet pressure 1 bar a, inlet temperature 20 °C, relative humidity 0% (dry).
²⁾ Free-field sound measurement in accordance with ISO 2151, tolerance ± 3 dB.
All models are also available as water-cooled versions. Please refer to the technical data sheet for the technical description.
Data from CompAir. Flow rate to ISO 1217, Annex C or E. We will be happy to determine with you which version and pressure are right for your system.
Frequently asked questions
Single-stage or two-stage?
For large compressors with many operating hours, electricity consumption accounts for almost all of the life-cycle costs. A two-stage FourCore therefore usually pays for itself quickly. We will do the calculation for you.
Fixed speed or variable speed (RS)?
A fixed-speed compressor is most economical when it runs at a steady load. If your compressed air demand fluctuates during the day, a variable speed RS compressor continuously adjusts its delivery and saves electricity. On request, we measure your demand with a compressed air analysis and tell you what is worthwhile.
Can the waste heat be used?
Yes. Up to 94 % of the energy consumed turns into heat. With heat recovery you can use it to heat water or rooms. More on this under Heat recovery.
Who maintains the compressor?
We do. As the CompAir partner for north-western Switzerland, we maintain and repair your system with genuine spare parts and service kits. If your compressed air supply fails, you can reach our on-call service on 062 552 00 88.
Downloads

Which compressor is right for your business?
Compressed air demand, pressure, operating times and available space determine the choice. We advise you, supply the compressor with air treatment, install the system and take care of service.