Zum Inhalt springen

CompAir L90 to L132

Oil-lubricated screw compressors 90 to 132 kW – single-stage and two-stage FourCore

From 90 to 132 kW, CompAir offers two options: the proven single-stage Classic series and the two-stage FourCore series with 110 and 132 kW, each with fixed or variable speed.

Compared with the single-stage models, the FourCore models save up to 13% energy and deliver up to 17% more air, on the same footprint.

Motor power

90 to 132 kW

Pressure

5 to 13 bar

Design

single- and two-stage

Why FourCore?

The FourCore GD10-DS airend combines two compression stages with four rotors in a semi-integrated housing. For the first time, a two-stage compressor is the size of a single-stage one.

Anyone who previously had no room for a two-stage system can now benefit from its efficiency. Often a smaller compressor is then sufficient.

  • Two-stage efficiency on the footprint of a single-stage machine
  • Up to 13% less energy, up to 17% more air
  • IE4 motor as standard
  • Constant intermediate pressure, fewer pipes, no leaks
  • Air- or water-cooled, fixed or variable speed
  • 10-year warranty on the airend

Classic series (single-stage)

The single-stage L90 to L132 are the proven choice when the investment cost is the priority. An innovative oil control valve increases their efficiency by up to 5%, depending on the model.

  • High reliability and clean compressed air
  • Delcos XL touchscreen controller
  • Small footprint
  • All service points easily accessible
  • High-performance separator and large-area aftercooler

Product images

Technical data

L110FC – L132FC with fixed speed

Compressor modelOperating pressureDrive motorFlow rate¹⁾Sound pressure level²⁾WeightDimensions L × W × H
[bar g][kW][m³/min][dB(A)][kg][mm]
L110FC7,511024,057244832907 × 2071 × 2193
8,511022,567244832907 × 2071 × 2193
1011021,217244832907 × 2071 × 2193
L132FC7,513228,797344982907 × 2071 × 2193
8,513225,277344982907 × 2071 × 2193
1013225,247344982907 × 2071 × 2193
CompAir 90 to 132 kW: L110FC – L132FC with fixed speed

L110FC RS – L132FC RS with variable speed drive

Compressor modelOperating pressureDrive motorFlow rate¹⁾Sound pressure level²⁾ at 70% loadWeightDimensions L × W × H
[bar g][kW][m³/min][dB(A)][kg][mm]
L110FC RS6 – 101109,16 – 24,697246722907 × 2071 × 2193
L132FC RS6 – 101329,16 – 29,397247362907 × 2071 × 2193
CompAir 90 to 132 kW: L110FC RS – L132FC RS with variable speed drive

L90 – L132 with fixed speed

Compressor modelOperating pressureDrive motorFlow rate¹⁾Sound pressure level²⁾WeightDimensions L × W × H
[bar g][kW][m³/min][dB(A)][kg][mm]
L907,59018,167324472290 × 1327 × 2039
109015,517324472290 × 1327 × 2039
139013,527324472290 × 1327 × 2039
L1107,511021,607525322290 × 1327 × 2039
1011018,857525322290 × 1327 × 2039
1311016,477525322290 × 1327 × 2039
L1327,513224,797627642290 × 1327 × 2039
1013221,517627642290 × 1327 × 2039
1313218,707627642290 × 1327 × 2039
CompAir 90 to 132 kW: L90 – L132 with fixed speed

L90RS – L132RS with variable speed drive

Compressor modelOperating pressureDrive motorFlow rate¹⁾ min – maxSound pressure level²⁾ at 70% loadWeightDimensions L × W × H
[bar g][kW][m³/min][dB(A)][kg][mm]
L90RS5 – 13905,20 – 18,167225792290 × 1327 × 2039
L110RS5 – 131105,10 – 21,527226042290 × 1327 × 2039
L132RS5 – 131325,10 – 24,767426552290 × 1327 × 2039
CompAir 90 to 132 kW: L90RS – L132RS with variable speed drive

L90ᵉ – L132ᵉ with fixed speed

Compressor modelOperating pressureDrive motorFlow rate¹⁾Sound pressure level²⁾WeightDimensions L × W × H
[bar g][kW][m³/min][dB(A)][kg][mm]
L90ᵉ7,59018,167324472290 × 1327 × 2039
109015,517324472290 × 1327 × 2039
L110ᵉ7,511021,67525322290 × 1327 × 2039
1011018,857525322290 × 1327 × 2039
L132ᵉ7,513224,797627642290 × 1327 × 2039
1013221,517627642290 × 1327 × 2039
CompAir 90 to 132 kW: L90ᵉ – L132ᵉ with fixed speed

¹⁾ Data measured and stated in accordance with ISO 1217, Ed. 4, Annex C & Annex E, within the tolerances given below: inlet pressure 1 bar a, inlet temperature 20 °C, relative humidity 0% (dry).
²⁾ Free-field sound measurement in accordance with ISO 2151, tolerance ± 3 dB.
All models are available as water-cooled versions. Please refer to the technical data sheet for the technical description.

Data from CompAir. Flow rate to ISO 1217, Annex C or E. We will be happy to determine with you which version and pressure are right for your system.

Frequently asked questions

Single-stage or two-stage?

Two-stage compressors cost a little more but use significantly less electricity. With many operating hours, they quickly pay for themselves. We will do the calculation for your business.

Fixed speed or variable speed (RS)?

A fixed-speed compressor is most economical when it runs at a steady load. If your compressed air demand fluctuates during the day, a variable speed RS compressor continuously adjusts its delivery and saves electricity. On request, we measure your demand with a compressed air analysis and tell you what is worthwhile.

Can the waste heat be used?

Yes. Up to 94 % of the energy consumed turns into heat. With heat recovery you can use it to heat water or rooms. More on this under Heat recovery.

Who maintains the compressor?

We do. As the CompAir partner for north-western Switzerland, we maintain and repair your system with genuine spare parts and service kits. If your compressed air supply fails, you can reach our on-call service on 062 552 00 88.

Downloads

Which compressor is right for your business?

Compressed air demand, pressure, operating times and available space determine the choice. We advise you, supply the compressor with air treatment, install the system and take care of service.

Your quote in three steps

New system, spare parts or maintenance: tell us what you need. We will get back to you personally with a quote tailored to your application.

Your request
Topic

Your details

Your enquiry

Fields marked with * are required. We only use your details to process your enquiry; more in our privacy policy.