Refrigeration dryers
Compressed air drying to +3 °C, economical and low-maintenance
Refrigeration dryers are the most common way of drying compressed air. They cool the air to around +3 °C so that the water vapour condenses and is drained off. The air is then reheated so that no more condensate forms in the network.
CompAir builds its refrigeration dryers in its own factory in Fogliano, Italy: non-cycling, cycling, variable speed, for Sub-Zero dew points and for high pressure up to 45 bar.
Pressure dew point
+3 °C, Sub-Zero −20 °C
Air quality
ISO 8573-1 class 4 or 3
Designs
5 product lines
Why a refrigeration dryer?
Moist compressed air makes pipes rust, valves fail and products spoil. Compression further increases the concentration of water and dirt. A refrigeration dryer removes most of the water and uses much less energy to do so than a desiccant dryer.
For workshops, manufacturing, automotive, chemicals and light industry, it is usually the most economical solution.
- Heat exchanger with low pressure drop
- Energy-saving mode at low load
- Anti-freeze mode to prevent icing
- Alarm display with alarm history
- Zero-loss condensate drainage
- Compact, easy to install and maintain
The product lines
CD series – non-cycling · CDF-ES – cycling · CD-VS – variable speed · CMT – Sub-Zero down to −20 °C · CDF HP – high pressure up to 45 bar
CD series – non-cycling
For constant compressed air demand, widest flow range

The non-cycling dryers of the CD series are ideal when air demand remains constant over time. Continuous dew point monitoring ensures reliable operation with low pressure drop. The new generation uses up to 10 % less electricity, has up to 27 % less pressure drop and is considerably smaller than its predecessors.
- Refrigerant with low global warming potential
- New heat exchangers, zero-loss drainage
- Air-cooled, Victaulic connections optional
- Complies with ISO 8573-1 and ISO 7183
CompAir dryers from 0.42 m³/min to 383.33 m³/min
| Model | Flow rate [3°C] | Power consumption | Power supply | Dew point | Max. pressure | Compressed air connection | Refrigerant | Dimensions [W × D × H] | Weight |
|---|---|---|---|---|---|---|---|---|---|
| [m³/min] | [kW] | [V/Ph/Hz] | [ISO class] | [bar g] | [BSP] | [mm] | [kg] | ||
| CD4F | 0,42 | 0,12 | 230/1/50 | 4 | 16 | ⅜" | R513A | 305 × 360 × 408 | 19 |
| CD7F | 0,70 | 0,14 | 230/1/50 | 4 | 16 | ½" | R513A | 390 × 432 × 453 | 26 |
| CD9F | 0,90 | 0,17 | 230/1/50 | 4 | 16 | ½" | R513A | 390 × 432 × 453 | 28 |
| CD12F | 1,20 | 0,17 | 230/1/50 | 4 | 16 | ½" | R513A | 390 × 432 × 453 | 28 |
| CD18F | 1,80 | 0,41 | 230/1/50 | 4 | 16 | ¾" | R513A | 420 × 516 × 563 | 36 |
| CD24F | 2,40 | 0,5 | 230/1/50 | 4 | 16 | ¾" | R513A | 420 × 516 × 563 | 42 |
| CD30F | 3,00 | 0,5 | 230/1/50 | 4 | 16 | ¾" | R513A | 420 × 516 × 563 | 44 |
| CD37F | 3,75 | 0,7 | 230/1/50 | 4 | 16 | 1" | R513A | 485 × 595 × 614 | 48 |
| CD43F | 4,33 | 0,81 | 230/1/50 | 4 | 16 | 1" | R513A | 485 × 595 × 614 | 49 |
| CD50F | 5,00 | 0,61 | 230/1/50 | 4 | 16 | 1 – ½" | R513A | 500 × 718 × 980 | 79 |
| CD60F | 6,00 | 0,74 | 230/1/50 | 4 | 16 | 1 – ½" | R513A | 500 × 718 × 980 | 79 |
| CD80F | 8,00 | 0,81 | 230/1/50 | 4 | 16 | 1 – ½" | R513A | 500 × 718 × 980 | 85 |
| CD100F | 10,00 | 1,26 | 230/1/50 | 4 | 16 | 2" | R513A | 779 × 720 × 1360 | 134 |
| CD130F | 13,00 | 1,67 | 400/3/50 | 4 | 13 | 2" | R513A | 779 × 720 × 1360 | 164 |
| CD160F | 15,83 | 2,03 | 400/3/50 | 4 | 13 | 2" | R513A | 779 × 720 × 1360 | 168 |
| CD216F | 21,67 | 2,24 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1539 | 234 |
| CD250F | 25,00 | 2,58 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1539 | 234 |
| CD300F | 30,00 | 3,1 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1539 | 234 |
| CD375F | 37,50 | 3,65 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1539 | 290 |
| CD430F | 43,33 | 4,22 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1539 | 290 |
| CDA533F | 53,33 | 6,38 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 417 |
| CDA700F | 70,00 | 5,96 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 465 |
| CDA800F | 80,00 | 6,81 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 465 |
| CD900F | 90,00 | 9,81 | 400/3/50 | 4 | 13 | DN150 PN16 | R513A | 1510 × 1500 × 1555 | 780 |
| CD1000F | 100,00 | 10,9 | 400/3/50 | 4 | 13 | DN150 PN16 | R513A | 1510 × 1500 × 1555 | 780 |
| CD1460F | 146,67 | 13,2 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1570 | 1058 |
| CD1600F | 160,00 | 13,56 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1570 | 1128 |
| CD1920F | 191,67 | 16,24 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1570 | 1205 |
| CD2920F | 293,33 | 26,4 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2116 |
| CD3200F | 320,00 | 27,12 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2256 |
| CD3840F | 383,33 | 32,48 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2720 |
Water-cooled from 10.00 m³/min to 383.33 m³/min
| Model | Flow rate [3°C] | Power consumption | Power supply | Dew point | Max. pressure | Compressed air connection | Refrigerant | Dimensions [W × D × H] | Weight |
|---|---|---|---|---|---|---|---|---|---|
| [m³/min] | [kW] | [V/Ph/Hz] | [ISO class] | [bar g] | [BSP] | [mm] | [kg] | ||
| CD100FW | 10,00 | 0,96 | 230/1/50 | 4 | 16 | 2" | R513A | 752 × 750 × 1273 | 143 |
| CD130FW | 13,00 | 1,55 | 400/3/50 | 4 | 13 | 2" | R513A | 752 × 750 × 1273 | 168 |
| CD160FW | 15,83 | 1,89 | 400/3/50 | 4 | 13 | 2" | R513A | 752 × 750 × 1273 | 168 |
| CD216FW | 21,67 | 2,04 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1422 | 265 |
| CD250FW | 25,00 | 2,36 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1422 | 265 |
| CD300FW | 30,00 | 2,83 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1422 | 265 |
| CD375FW | 37,50 | 3,38 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1422 | 375 |
| CD430FW | 43,33 | 3,90 | 400/3/50 | 4 | 14 | 3" | R513A | 806 × 1012 × 1422 | 375 |
| CDA533FW | 53,33 | 5,7 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 460 |
| CDA700FW | 70,00 | 5,38 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 486 |
| CDA800FW | 80,00 | 6,15 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 486 |
| CD900FW | 90,00 | 8,98 | 400/3/50 | 4 | 13 | DN150 PN16 | R513A | 1510 × 1500 × 1437 | 740 |
| CD1000FW | 100,00 | 9,973 | 400/3/50 | 4 | 13 | DN150 PN16 | R513A | 1510 × 1500 × 1437 | 740 |
| CD1460FW | 146,67 | 12,14 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1440 | 1010 |
| CD1600FW | 160,00 | 12,43 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1440 | 1060 |
| CD1920FW | 191,67 | 14,9 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 2270 × 1590 × 1440 | 1117 |
| CD2920FW | 293,33 | 24,28 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2020 |
| CD3200FW | 320,00 | 24,86 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2120 |
| CD3840FW | 383,33 | 29,8 | 400/3/50 | 4 | 13 | 2 x DN200 PN16 | R513A | 4600 × 1590 × 1570 | 2234 |
CDF-ES – cycling
For fluctuating demand: saves electricity at part load

In the cycling dryer, a glycol circuit cools the compressed air. When demand drops, the refrigeration compressor can switch off while the glycol continues to cool. This saves energy when air demand rises and falls over the course of the day.
- Up to 10 % less electricity, up to 27 % less pressure drop
- Up to 40 % smaller footprint
- Three-layer heat exchangers, glycol pumps
- Zero-loss Smart Drain
- iConn-ready
Technical data
| Model | Flow rate 3°C | Power consumption | Power supply | Dew point | Max. pressure | Compressed air connection | Refrigerant | Dimensions [W × D × H] | Weight | Recommended filter** |
|---|---|---|---|---|---|---|---|---|---|---|
| [m³/min] | [kW] | [V/Ph/Hz] | [ISO class] | [bar g] | [BSP] | [mm] | [kg] | |||
| CD9F-ES | 0,90 | 0,24 | 230/1/50 | 4 | 16 | ½” | R513A | 386 × 500 × 651 | 39 | CF013 |
| CD12F-ES | 1,20 | 0,32 | 230/1/50 | 4 | 16 | ½” | R513A | 386 × 500 × 651 | 43 | CF013 |
| CD18F-ES | 1,80 | 0,45 | 230/1/50 | 4 | 16 | ¾” | R513A | 386 × 500 × 651 | 48 | CF018 |
| CD24F-ES | 2,40 | 0,51 | 230/1/50 | 4 | 16 | ¾” | R513A | 386 × 500 × 651 | 51 | CF025 |
| CD30F-ES | 3,00 | 0,54 | 230/1/50 | 4 | 16 | 1” | R513A | 423 × 567 × 771 | 67 | CF032 |
| CD40F-ES | 4,00 | 0,846 | 230/1/50 | 4 | 16 | 1” | R513A | 423 × 567 × 771 | 71 | CF067 |
| CD50F-ES | 5,00 | 0,65 | 230/1/50 | 4 | 16 | 1½” | R513A | 500 × 718 × 980 | 105 | CF067 |
| CD60F-ES | 6,00 | 0,78 | 230/1/50 | 4 | 16 | 1½” | R513A | 500 × 718 × 980 | 108 | CF067 |
| CD80F-ES | 8,00 | 0,84 | 230/1/50 | 4 | 16 | 1½” | R513A | 500 × 718 × 980 | 120 | CF0100 |
| CD100F-ES | 10,00 | 1,05 | 230/1/50 | 4 | 16 | 2” | R513A | 779 × 720 × 1360 | 186 | CF0100 |
| CD130F-ES | 13,00 | 1,62 | 400/3/50 | 4 | 13 | 2” | R513A | 779 × 720 × 1360 | 227 | CF0133 |
| CD160F-ES | 15,83 | 2,08 | 400/3/50 | 4 | 13 | 2” | R513A | 779 × 720 × 1360 | 237 | CF0167 |
| CD216F-ES | 21,67 | 2,32 | 400/3/50 | 4 | 14 | 3” | R513A | 806 × 1012 × 1539 | 394 | CF0260 |
| CD250F-ES | 25,00 | 2,68 | 400/3/50 | 4 | 14 | 3” | R513A | 806 × 1012 × 1539 | 394 | CF0260 |
| CD300F-ES | 30,00 | 3,22 | 400/3/50 | 4 | 14 | 3” | R513A | 806 × 1012 × 1539 | 394 | CF0305 |
| CD375F-ES | 37,50 | 3,74 | 400/3/50 | 4 | 14 | 3” | R513A | 806 × 1012 × 1539 | 399 | CF0383 |
| CD430F-ES | 43,33 | 4,32 | 400/3/50 | 4 | 14 | 3” | R513A | 806 × 1012 × 1539 | 399 | CF0450 |
| CDA533F-ES | 53,33 | 6,68 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 810 | CF0700 |
| CDA700F-ES | 70,00 | 6,80 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 840 | CF0700 |
| CDA800F-ES | 80,00 | 7,18 | 400/3/50 | 4 | 14 | DN150 PN16 | R513A | 880 × 1819 × 1796 | 840 | CF0950 |
| CDA900F-ES | 90,00 | 9,12 | 400/3/50 | 4 | 13 | DN150 PN16 | R513A | 1140x2135x1910 | 1123 | CF0950 |
| CDA1100F-ES | 110,00 | 11,12 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 1140x2135x1910 | 1152 | CF1250 |
| CDA1250F-ES | 125,00 | 13,42 | 400/3/50 | 4 | 13 | DN200 PN16 | R513A | 1140x2135x1910 | 1170 | CF1250 |
Features
| Features | CD9F-ES – CD40F-ES | CD50F-ES – CD80F-ES | CD100F-ES – CD160F-ES | CD216F-ES – CD900F-ES |
|---|---|---|---|---|
| Dew point display | • | • | • | • |
| On/off switch | • 1] | • | • | • |
| Remote alarm signal connection | • | • | • | • |
| High-pressure switch | • | • | ||
| Fan pressure switch | • 2] | • | ||
| Alarm history (latest entries) | 10 | 10 | 10 | 50 |
| Heat exchanger layers | 1 × 3 | 1 × 3 | 1 × 3 | 2 × 2 |
| Frost protection | • | • | • | • |
| Zero-loss intelligent drain | • | • | • | • |
| Glycol manifold | • | • | • | • |
| Aluminium heat exchanger | • | • | • | • |
| % energy saving display | • | • | • | • |
| Number of sensors* | 2 | 2 | 2 | 4 |
| Fast restart | • | • |
• Standard feature
* 2 sensors = glycol control and refrigeration circuit, 4 sensors = glycol control, refrigerant suction, ambient temperature, compressor oil
** We recommend installing additional pre-filters and after-filters depending on air quality requirements
1] Only on CD30F-ES & CD40F-ES
2] Only on CD130F-ES & CD160F-ES
CD-VS – variable speed
Inverter for compressor and fan, R513A refrigerant

The CD-VS continuously adapts the output of the refrigeration compressor and fans to the actual heat load. This keeps the dew point very stable and lowers operating costs. At very low load it can operate in cycling or non-cycling mode.
- R513A refrigerant: low GWP, non-toxic, non-flammable
- DMC55 controller with 4.3-inch touchscreen
- Display of current power consumption
- Weekly timer, Modbus RS485
| Model | Refrigerant | Flow rate | Pressure drop | Connections | Power supply | Dimensions [mm] | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| [m³/h] | [l/min] | [scfm] | [bar] | [Ø] | [Ph/V/Hz] | A | B | C | [kg] | ||
| CD21VS | R513A | 1260 | 21000 | 742 | 0,1 | DN 80 PN16 | 3/400/50-60 | 790 | 1000 | 1465 | 249 |
| CD30VS | R513A | 1800 | 30000 | 1060 | 0,12 | DN 80 PN16 | 3/400/50-60 | 790 | 1000 | 1465 | 276 |
| CD36VS | R513A | 2208 | 36800 | 1300 | 0,13 | DN 80 PN16 | 3/400/50-60 | 790 | 1000 | 1465 | 296 |
| CD40VS | R513A | 2400 | 40000 | 1413 | 0,09 | DN 100 PN16 | 3/400/50-60 | 1135 | 1205 | 1750 | 510 |
| CD50VS | R513A | 3000 | 50000 | 1766 | 0,08 | DN 100 PN16 | 3/400/50-60 | 1135 | 1205 | 1750 | 590 |
| CD60VS | R513A | 3600 | 60000 | 2119 | 0,12 | DN 100 PN16 | 3/400/50-60 | 1135 | 1205 | 1750 | 597 |
| CD72VS | R513A | 4416 | 73600 | 2600 | 0,13 | DN 100 PN16 | 3/400/50-60 | 1135 | 1205 | 1750 | 669 |
| CD90VS | R513A | 5400 | 90000 | 3178 | 0,12 | DN 150 PN16 | 3/400/50 | 1300 | 1750 | 1810 | 1000 |
| CD110VS | R513A | 6624 | 110400 | 3900 | 0,13 | DN 150 PN16 | 3/400/50 | 1300 | 1750 | 1810 | 1110 |
| CD120VS | R513A | 7200 | 120000 | 4238 | 0,12 | DN 200 PN16 | 3/400/50 | 1400 | 2200 | 1870 | 1330 |
| CD150VS | R513A | 8832 | 147200 | 5200 | 0,13 | DN 200 PN16 | 3/400/50 | 1400 | 2200 | 1870 | 1510 |
Models with 60 Hz power supply on request.
Options & accessories – WC: water cooling with shell-and-tube condenser
Options & accessories – BY-PASS: bypass group (only for CD21VS–CD36VS)
CMT – Sub-Zero down to −20 °C
Sub-zero dew point at the cost of a refrigeration dryer

The CMT is a regenerative refrigeration dryer: it reaches a pressure dew point of −20 °C, i.e. ISO class 3, while remaining as economical and low-maintenance as a refrigeration dryer. For many applications that previously required a desiccant dryer, it is the more cost-effective solution.
- Pressure dew point −20 °C (ISO class 3)
- Multi-stage cooling with pre-cooler and reheating
- Less energy than a desiccant dryer
- No desiccant, no purge air loss
| Model | Capacity | Operating performance | Dimensions [mm] | Weight | ||
|---|---|---|---|---|---|---|
| [m³/hr] | [kW] | Length | Width | Height | [kg] | |
| CMT60 | 360 | 1,46 | 1063 | 899 | 1767 | 352 |
| CMT70 | 420 | 1,78 | 1063 | 899 | 1670 | 352 |
| CMT266 | 1600 | 5,75 | 1500 | 1400 | 1898 | 750 |
* The data refer to an air intake of FAD 20 °C, 1 bar and the following operating conditions: 7 bar working pressure, −20 °C pressure dew point, 25 °C ambient temperature, 35 °C compressed air inlet temperature.
CDF HP – high pressure up to 45 bar
For PET blow moulding, waterjet cutting and valve testing

Ten robust, compact high-pressure dryers for working pressures up to 45 bar and ambient temperatures up to 50 °C. They maintain a pressure dew point of +3 °C at 88 to 1,200 m³/h (at 40 bar).
- Three-in-one stainless steel heat exchanger
- 10% more efficient than their predecessors, R513A refrigerant
- Variable fan speed, hot gas bypass
- Dew point display, remote alarm, alarm history
| Model | Part no. | Flow rate 40 bar g | Maximum pressure | Power | Refrigerant | Dimensions W×D×H | Connections | Weight | |
|---|---|---|---|---|---|---|---|---|---|
| [CCN] | [m³/h] | [m³/min] | [bar] | [kW] | [mm] | [BSP] | [kg] | ||
| CD14F HP45 | 47757390001 | 88 | 1,47 | 45 | 0,371 | R513A | 390 × 432 × 443 | 3/4" | 27 |
| CD18F HP45 | 47757391001 | 108 | 1,80 | 45 | 0,371 | R513A | 390 × 432 × 443 | 3/4" | 28 |
| CD30F HP45 | 47757392001 | 180 | 3,00 | 45 | 0,605 | R513A | 420 × 516 × 551 | 3/4" | 31 |
| CD38F HP45 | 47757393001 | 225 | 3,75 | 45 | 0,605 | R513A | 420 × 516 × 551 | 3/4" | 33 |
| CD45F HP45 | 47757394001 | 270 | 4,50 | 45 | 0,879 | R513A | 420 × 516 × 551 | 3/4" | 36 |
| CD60F HP45 | 47757395001 | 360 | 6,00 | 45 | 1,405 | R513A | 420 × 516 × 551 | 3/4" | 40 |
| CD80F HP45 | 47757396001 | 480 | 8,00 | 45 | 1,41 | R407C | 500 × 680 × 980 | 1-1/4" | 80 |
| 47757397001 | 480 | 8,00 | 45 | 1,71 | R407C | 500 × 680 × 980 | 1-1/4" | 80 | |
| CD110F HP45 | 47757398001 | 660 | 11,00 | 45 | 1,92 | R407C | 500 × 680 × 980 | 1-1/4" | 83 |
| 47757399001 | 660 | 11,00 | 45 | 2,28 | R407C | 500 × 680 × 980 | 1-1/4" | 83 | |
| CD165F HP45 | 47757400001 | 990 | 16,50 | 45 | 1,92 | R407C | 520 × 770 × 1195 | 1-1/4" | 110 |
| 47757401001 | 990 | 16,50 | 45 | 2,28 | R407C | 520 × 770 × 1195 | 1-1/4" | 110 | |
| CD200F HP45 | 47757402001 | 1200 | 20,00 | 45 | 2,24 | R407C | 520 × 770 × 1195 | 1-1/4" | 120 |
| 47757403001 | 1200 | 20,00 | 45 | 2,28 | R407C | 520 × 770 × 1195 | 1-1/4" | 120 | |
Frequently asked questions
Refrigeration dryer or desiccant dryer?
A refrigeration dryer reaches a pressure dew point of +3 °C and is sufficient for most applications; it needs little energy and maintenance. If pipes run outdoors or in cold rooms, or the process requires very dry air, you need a desiccant dryer with −40 °C or −70 °C. In between lies the Sub-Zero dryer with −20 °C.
What is the pressure dew point?
The temperature at which the moisture in the compressed air begins to condense. The lower the pressure dew point, the drier the air. ISO 8573-1 divides air quality into classes accordingly: class 4 corresponds to +3 °C, class 3 to −20 °C, class 2 to −40 °C and class 1 to −70 °C.
Cycling or non-cycling?
If your air demand is steady, a non-cycling dryer is the simpler choice. If it fluctuates widely, a cycling or variable speed dryer saves electricity because it works less at part load.
What maintenance does a refrigeration dryer need?
Very little: check and clean the condensate drain, filters and heat exchanger, and check the dew point. We take care of this as part of compressor maintenance.
Who maintains the compressor?
We do. As the CompAir partner for north-western Switzerland, we maintain and repair your system with genuine spare parts and service kits. If your compressed air supply fails, you can reach our on-call service on 062 552 00 88.
Downloads

Which dryer is right for your system?
Flow rate, pressure, required pressure dew point and the environment determine the choice. We size the dryer and filters to suit your compressor, install them and take care of service.