Rotary vane pumps DC50 to DC90

Fürgut types KL, SL and KSL

Fürgut’s largest DC rotary vane pumps deliver considerably more gas and reach higher pressures and vacuum levels than the small ranges, while still drawing little current.

Seven versions for 12 and 24 V cover a wide range.

Flow rate

up to 13 l/min

Vacuum

up to 815 mbar

Pressure

up to 1,500 mbar

Voltage

12 and 24 V

Why the DC50 to DC90?

The large types also convey oil-free with special carbon vanes in a stainless steel housing. On larger motors, a shaft seal seals the motor shaft.

  • Virtually pulsation-free delivery
  • Flow rate linearly adjustable via the voltage
  • Very low current consumption
  • Very long service life at reduced voltage
  • Oil-free, special carbon vanes

Typical applications

Gas analysis

Larger sample flows and longer lines.

Vacuum for devices

Holding, suction and degassing.

Compressed air on a small scale

Pressure for valves and actuators in devices.

Mobile applications

Operation on 12 or 24 V on-board power.

Technical data

Types: DC../50KL, DC../80KL, DC../90KL, DC../80SL, DC../80KSL, DC../90SL, DC../90KSL. Each pump is specified at several operating voltages: at rated voltage and at reduced voltage. The current applies at minimum and maximum load in each case.

DC../50KL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/50KL160000,662,012,06,11,01,9780821,03,3140071
9,04,30,81,7730790,82,5100065
6,02,80,71,5580700,71,764057
DC24/50KL161000,661,024,06,40,61,0785840,61,6125073
18,04,70,60,9730810,61,395067
12,02,90,40,7670730,41,058062
Rotary vane pumps DC50 to DC90: DC../50KL

DC../80KL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/80KL160010,692,012,09,61,72,7765751,74,0100072
9,06,61,22,3635721,23,174569
6,04,10,91,8425650,92,140565
DC24/80KL161010,691,024,010,40,81,476577––––
18,07,70,61,2680740,71,889069
12,04,60,51,0480660,51,255064
Rotary vane pumps DC50 to DC90: DC../80KL

DC../90KL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/90KL160020,692,012,012,01,53,375078––––
9,08,51,23,0590731,33,561070
6,05,20,92,1300650,92,331563
DC24/90KL161020,691,024,011,70,91,777079––––
18,08,30,71,5645740,71,973570
12,05,20,51,1430680,51,244065
Rotary vane pumps DC50 to DC90: DC../90KL

DC../80SL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/80SL159890,792,712,010,31,52,5800831,76,4150072
9,07,81,22,5770801,34,9110067
6,04,90,92,1620721,03,270059
DC24/80SL169910,791,224,09,10,71,3770840,73,0145074
18,06,60,51,1710790,52,4110068
12,04,40,41,0580740,51,670062
Rotary vane pumps DC50 to DC90: DC../80SL

DC../80KSL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/80KSL160030,792,8112,09,91,52,5800831,65,4130072
9,07,51,32,4760801,34,493067
6,04,71,02,1640721,03,073059
DC24/80KSL161030,791,2224,09,00,71,2785840,81,9110074
18,06,60,61,0740790,71,9120068
12,04,30,51,0630740,51,475062
Rotary vane pumps DC50 to DC90: DC../80KSL

DC../90SL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/90SL159880,792,712,013,01,63,0810842,27,6–81
9,09,91,33,1790811,85,4–74
6,06,31,12,8690731,13,470069
DC24/90SL169870,791,224,011,90,81,5795790,93,5–74
18,07,90,71,5740760,72,6–73
12,05,00,51,3595690,51,864066
Rotary vane pumps DC50 to DC90: DC../90SL

DC../90KSL

TypeItem no.WeightRated currentOperating voltageFlow rateVacuum operationPressure operation
[kg][A][V][l/min]Current min. [A]Current max. [A][mbar][dB(A)]Current min. [A]Current max. [A][mbar][dB(A)]
DC12/90KSL160040,792,8112,012,81,83,280075––––
9,09,31,33,1750741,45,1110068
6,05,61,02,8540651,03,258062
DC24/90KSL161040,791,2224,012,70,81,681576––––
18,08,70,71,5725710,72,4100069
12,05,50,51,3550660,51,562063
Rotary vane pumps DC50 to DC90: DC../90KSL

Rotary vane pump for non-toxic, non-flammable and non-explosive gases
Illustrations/data/diagrams not binding (50KL, 80KL, 90KL, 90SL, 90KSL)
Illustration not binding (80SL, 80KSL)

Dimensions

TypeLength [mm]Motor Ø [mm]Pump head [mm]Connection nozzle [mm]Connection spacing [mm]Electrical connection
DC../50KL105,542Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 300 mm
DC../80KL108,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 300 mm
DC../90KL108,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 300 mm
DC../80SL123,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 1,000 mm
DC../80KSL123,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 300 mm
DC../90SL123,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 1,000 mm
DC../90KSL123,942Ø 50Ø 5,2 / Ø 4,314 / 12,5Leads 300 mm
Rotary vane pumps DC50 to DC90 – dimensions

Frequently asked questions

Which gases can be conveyed?

The pumps are designed for non-toxic, non-flammable and non-explosive gases. For other media, we will be glad to advise you on alternatives.

Can I run the pump at a lower voltage?

Yes. The DC pumps can be operated at reduced voltage; flow rate and pressure then decrease and service life increases. The table shows the values for several voltages.

How long does a miniature rotary vane pump last?

Depending on the load, the special carbon vanes reach up to 10,000 operating hours. At reduced voltage and low load they last particularly long.

Are the pumps suitable for installation in devices?

Yes, that is what they are made for: small, light and with low current consumption, for example for analysers, medical and laboratory technology. For series production, we define the right version with you.

Where can I get pumps and spare parts?

From us. We supply Fürgut pumps individually and for series production, advise you on the selection and obtain replacements when a pump needs to be exchanged after many operating hours.

Downloads

Which pump suits your device?

Flow rate, pressure or vacuum, voltage and installation space determine the choice. We advise you and supply the right Fürgut pump, including for series production.

Your quote in three steps

New system, spare parts or maintenance: tell us what you need. We will get back to you personally with a quote tailored to your application.

Your request
Topic

Your details

Your enquiry

Fields marked with * are required. We only use your details to process your enquiry; more in our privacy policy.